| Availability: | |
|---|---|
| Quantity: | |
ZSJH
Galvanized square and rectangular steel tubes combine hollow steel sections with a protective zinc coating. Their flat faces and practical connection surfaces make them suitable for building frames, fencing, support structures and equipment fabrication.
Available in square hollow sections (SHS) and rectangular hollow sections (RHS), these tubes can be specified in different section sizes and wall thicknesses to meet strength, stiffness, weight and fabrication requirements.
Square Hollow Sections — SHS
Equal external width and height provide matching section properties about the two principal axes. Square tubes are commonly selected for posts, columns, fence frames and assemblies requiring a balanced profile.
Rectangular Hollow Sections — RHS
Different external width and height provide different bending stiffness about each principal axis. Rectangular tubes are useful for beams, horizontal rails and equipment frames where section orientation can improve performance within the available space.
Both profiles feature rounded corners. Corner radii, dimensional tolerances and weld-seam position should be considered when designing close-fitting connections or fabricated assemblies.
| Parameter | Specification / Ordering Requirement |
|---|---|
| Section Type | Square (SHS) or rectangular (RHS) hollow section |
| External Dimensions | Width × height in mm |
| Wall Thickness | Specified thickness in mm, with applicable tolerance |
| Length | Fixed or cut lengths, subject to confirmation |
| Base Material | Carbon steel; grade selected for the application |
| Manufacturing Route | Typically cold-formed and longitudinally welded |
| Galvanizing Method | Pre-galvanized or hot-dip galvanized after manufacture, as agreed |
| Coating Requirement | Applicable coating standard, designation, thickness or mass criteria |
| Surface Condition | Galvanized finish; additional finishing requirements to be specified |
| End Condition | Plain cut or deburred; other processing subject to suitability |
| Inspection | Dimensions, wall thickness, straightness, twist, surface and agreed coating checks |
| Documentation | Material and inspection records as agreed at quotation |
Ordering format:
Width × Height × Wall Thickness × Length + Steel Grade + Section Standard + Galvanizing Requirements.

Wall thickness affects section weight, local buckling resistance, connection performance and fabrication options.
| Wall Selection | Typical Considerations |
|---|---|
| Thinner Walls | Lower weight for light frames, fence infill and non-load-bearing assemblies |
| Intermediate Walls | A balance of weight and stiffness for general frames and fabricated supports |
| Thicker Walls | Greater section area and improved local resistance where justified by design |
These are selection principles rather than fixed product categories. Structural capacity also depends on external dimensions, steel grade, member length, loading, restraint and connections.
Steel wall thickness and zinc coating thickness are separate parameters: the steel wall contributes to structural performance; the zinc coating provides corrosion protection.
Pre-galvanized tubing is formed from previously zinc-coated strip or sheet. It offers a practical finish for light fabrication, but weld-seam treatment and protection of cut ends must be specified.
Hot-dip galvanizing after manufacture coats the completed tube or fabricated assembly. Suitable preparation, venting and drainage are necessary for hollow components.
Select the galvanizing route according to exposure and fabrication sequence. Outdoor frames and fencing require attention to rainwater, condensation, exposed connections and water-trapping details. Coastal, buried or chemically aggressive environments may require additional protection.
Cutting, drilling and welding after galvanizing can expose steel. Include an appropriate coating-repair procedure in the fabrication specification.
| Application | Typical Uses | Main Selection Priorities |
|---|---|---|
| Building Frames | Columns, beams, secondary framing and canopy frames | Structural grade, section properties, buckling and connection design |
| Fencing | Posts, rails, gates and infill frames | Appearance, wall thickness, wind loading and outdoor protection |
| Support Structures | Brackets, equipment stands and service-support frames | Loads, restraint, fixing details and corrosion exposure |
| Equipment Manufacturing | Machine bases, enclosure frames and fabricated platforms | Stiffness, dimensional consistency, vibration and mounting details |
For rectangular members, orientation matters: rotating the section changes its bending stiffness. Load-bearing sections should be selected using the applicable design code and verified section properties.
| Term / Marking | Meaning |
|---|---|
| SHS | Square Hollow Section |
| RHS | Rectangular Hollow Section |
| B × H × t | External width × external height × wall thickness |
| L | Length |
| Steel Grade | Material designation under the specified standard |
| Heat / Batch Number | Traceability reference |
| Coating Reference | Agreed galvanizing method and coating specification |
Illustrative size examples:
SHS 50 × 50 × 2.0 mm: square section with 50 mm external sides and 2.0 mm specified wall thickness.
RHS 100 × 50 × 3.0 mm: rectangular section with 100 × 50 mm external dimensions and 3.0 mm specified wall thickness.
Illustrative inquiry:
Galvanized RHS — 100 × 50 × 3.0 mm × 6,000 mm — Steel Grade and Section Standard as Specified — Hot-Dip Galvanizing After Manufacture — Plain Ends — For Equipment Support Frames
These examples describe ordering information and do not confirm stock availability. Internal dimensions depend on actual wall thickness and corner geometry.

Specify the hollow-section requirements and galvanizing requirements separately.
| Standard | Relevant Scope |
|---|---|
| EN 10219-1 | Technical delivery requirements for applicable cold-formed welded structural hollow sections |
| EN 10219-2 | Tolerances, dimensions and sectional properties |
| ASTM A500/A500M | Cold-formed welded and seamless carbon steel structural tubing, including square and rectangular shapes |
| EN 10346 / ASTM A653/A653M | Relevant starting-strip or sheet standards for pre-galvanized products |
| ISO 1461 | Galvanized fabricated articles within its scope; applicability depends on the galvanizing route |
EN 10219 and ASTM A500 address structural tubing requirements; they do not, by themselves, define a complete galvanizing specification. ISO 1461 excludes tubes and pipes galvanized in automatic plants. Confirm the applicable coating standard and its scope before ordering.
Compliance is specific to the ordered product, standard edition, steel grade and supporting documentation.
Should I choose square or rectangular tubing?
Square tubing suits balanced profiles and many posts or frames. Rectangular tubing offers different stiffness in each direction, making it useful where loading and available space favour a particular orientation.
Does a thicker wall always mean a better product?
No. The appropriate wall thickness meets the design and fabrication requirements without unnecessary weight or cost. External size and member length also strongly affect performance.
Can galvanized tubes be used for structural frames?
Yes, when the material, section properties, connections and documentation meet the project requirements. A galvanized finish alone does not establish structural suitability.
Are the internal surfaces galvanized?
Coverage depends on the coating route. Pre-galvanized strip carries coating on its original faces, but welding affects the seam. For galvanizing after manufacture, internal coverage depends on access, preparation and drainage. State internal coating requirements explicitly.
Can the tubes be welded or drilled?
Yes, using suitable procedures. Processing can damage the zinc coating, so exposed areas need repair. Welding galvanized steel also requires appropriate fume controls.
What should I specify for equipment frames?
Include section dimensions, grade, straightness, twist, length tolerance, mounting details and required finish. Close-fitting inserts may also require control of the internal weld bead and corner geometry.
ZSJHSTEEL helps overseas buyers develop clear specifications for galvanized square and rectangular tubing—from section dimensions and wall thickness to coating requirements and fabrication details.
For contractors, fencing suppliers and equipment manufacturers, we support coordinated sourcing and quotation planning. Inspection documents, identification, packing and delivery requirements can be agreed before ordering to match the project’s procurement needs.
Send us your:
Section type: SHS or RHS.
Width × height × wall thickness and required length.
Steel grade and applicable section standard.
Galvanizing method and coating requirements.
Intended application and service environment.
Quantity, processing requirements and required documents.
Delivery destination and target schedule.
Contact ZSJHSTEEL for galvanized hollow sections matched to your building frames, fencing, support structures or equipment fabrication requirements.
content is empty!