| Availability: | |
|---|---|
| Quantity: | |
ZSJH
ZSJH supplies flanged ductile iron pipes for pump stations, water treatment plants, valve chambers and industrial water systems. Available configurations can include double-flanged, flange-and-spigot, and flange-and-socket ends, selected to match equipment connections and pipeline layouts.
For reliable installation, the specification should define more than pipe diameter. Flange standard, PN designation, sealing-face requirements, end configuration and finished length must be coordinated with the adjoining components.
| Product Configuration | End Arrangement | Typical Use |
|---|---|---|
| Double Flanged Ductile Iron Pipe | A flange at each end | Connecting valves, pumps, meters and other flanged equipment; specified-length pipe spools |
| Flange and Spigot Ductile Iron Pipe | One flanged end and one plain spigot | Transitioning from a flanged component to a compatible socket-ended pipeline |
| Flange and Socket Ductile Iron Pipe | One flanged end and one socket | Connecting a flanged component to the compatible spigot end of an adjoining pipe |
Double-flanged pipes provide bolted connections at both ends. Their face-to-face length and relative bolt-hole orientation are particularly important when fitting between fixed equipment.
Flange-and-spigot pipes combine a bolted flange connection with a plain insertion end. Spigot diameter, chamfer and insertion requirements must match the receiving socket.
Flange-and-socket pipes combine a flange with a gasket-equipped socket. Socket geometry and gasket profile must match the adjoining pipe system.
Flanged joints are rigid connections. A standard socket connection on a flange-and-socket pipe does not automatically provide axial restraint.

The examples below identify common procurement fields. Availability depends on the selected diameter, design and manufacturing specification.
| Parameter | Common Designation or Example | Information to Confirm |
|---|---|---|
| Product material | Ductile cast iron | Material requirements and applicable product standard |
| Nominal diameter | DN100, DN150, DN200, DN250, DN300 and other specified sizes | Required DN and compatibility with adjoining components |
| End configuration | Double flange; flange–spigot; flange–socket | Connection required at each end |
| Flange standard | EN 1092-2 for relevant cast-iron flange specifications | Standard edition, flange type, dimensions and drilling |
| Nominal pressure designation | PN10, PN16, PN25, PN40 | Required designation and allowable service conditions |
| Flange dimensions | Outside diameter, bolt-circle diameter, hole quantity and hole diameter | Compatibility with mating flanges |
| Flange face | Face type and surface finish specified by the design | Gasket compatibility and sealing requirements |
| Pipe length | Custom face-to-face or drawing-defined length | Measurement points, tolerance and installation allowance |
| Pipe wall specification | Thickness or class under the applicable product system | Pressure, external loads and flange attachment requirements |
| Internal lining | Cement mortar lining or specified alternative | Water chemistry and drinking-water requirements |
| External coating | Specified protective coating system | Installation environment, preparation and coating thickness |
| Accessories | Gaskets, bolts, nuts and washers | Dimensions, materials, quantities and whether included |
Double Flanged Ductile Iron Pipe, DN200, PN16, flanges to EN 1092-2, face-to-face length 1,000 mm, specified internal lining and external coating.
This is an example specification, not a universal product model. The final order should also confirm flange construction, face requirements, tolerances, bolt-hole orientation and documentation.
For an EN 545 flanged ductile iron pipe, identify the applicable flange dimensional standard separately. EN 1092-2 is a relevant standard for cast-iron flanges within the European PN system.
To check compatibility, confirm:
Nominal diameter and PN designation
Flange standard and edition
Bolt-circle diameter, hole quantity and hole diameter
Sealing-face type and gasket requirements
Flange orientation where installation between fixed components requires it
Matching DN and PN alone should not replace a dimensional check, particularly when connecting components supplied under different standard systems.
PN is a nominal pressure designation used to identify a component's pressure-related characteristics within a defined standard system. Common designations include PN10, PN16, PN25 and PN40.
A PN16 flanged ductile iron pipe should not be selected solely on the assumption that every assembly can operate at 16 bar under all conditions. Allowable operating, surge and test pressures must be checked against the manufacturer's data, service temperature and complete assembly.
The component with the lowest applicable rating can limit the system's performance.
A custom length flanged ductile iron pipe helps match the space between valves, equipment and fixed pipeline connections.
For double-flanged pipes, specify the face-to-face length between the flange sealing faces, together with the required tolerance. The available installation gap must also account for mating gaskets and any dismantling or adjustment components.
For flange-and-spigot and flange-and-socket pipes, provide a dimensioned drawing. Overall length and effective installed length differ because the socket connection requires insertion or overlap.
For accurate production and installation, confirm:
Length measurement points and tolerances
Flange-face alignment and bolt-hole orientation
Required spigot insertion depth
Space for bolting, maintenance and dismantling
Minimum and maximum manufacturing lengths
Bolts should not be used to force a misaligned or incorrectly sized pipe spool into position.

| Standard | Relevance to the Product |
|---|---|
| EN 545 | Ductile iron pipes, fittings, accessories and joints for water pipelines |
| ISO 2531 | Ductile iron pipes, fittings, accessories and joints for water applications |
| EN 1092-2 | Circular cast-iron flanges within the PN designation system |
| ISO 4179 | Cement mortar lining for ductile iron pipes and fittings |
| ANSI/AWWA C115 | Ductile iron pipe with threaded flanges for projects using this specification |
| ANSI/AWWA C104 | Cement mortar lining within the AWWA specification system |
| EN 598 | Relevant to separately specified drainage and sewerage configurations |
The purchase specification should identify the required standards and editions. An EN flange configuration and an AWWA threaded-flange configuration are different supply arrangements and should be reviewed separately.
Potable-water approvals for linings, gaskets and other water-contact materials must also meet the destination project's requirements.
Ductile iron flanged pipe for pump stations connects pumping equipment, isolation valves, check valves and associated piping. Correct spool length, flange alignment and pipe supports help control installation loads on equipment.
Flanged ductile iron pipe for water treatment plants is suitable for specified interconnecting pipework around treatment equipment, valve assemblies and process-water systems. Lining and gasket selection must suit the conveyed water.
Double-flanged spools provide defined connections between valves, flow meters and other flanged components. Allow sufficient access for bolt tightening and future maintenance.
Flange-and-spigot and flange-and-socket configurations connect flanged equipment to compatible gasket-jointed pipelines. Any required thrust restraint must be addressed in the project design.
Specified flanged pipework can serve industrial water supply and utility systems where pressure, temperature, medium compatibility and support arrangements have been verified.
Project-specific procurement
Send your drawings or bill of quantities so the enquiry can be organized around the required end configurations, diameters, flange standards and lengths.
Coordinated pipe and accessory sourcing
Discuss compatible fittings, gaskets and fasteners alongside the pipe supply, with included items clearly identified in the quotation.
Clear technical confirmation
Agree on the offered configuration, dimensional requirements, protective systems and inspection documents before ordering.
Export delivery coordination
Discuss packing, protection of flange faces, shipment requirements and delivery schedules as part of the supply package.
ZSJH works with contractors, distributors and procurement teams seeking a flanged ductile iron pipe supplier for clearly specified water infrastructure products.
Use double-flanged pipes between compatible flanged connections. Choose flange-and-spigot or flange-and-socket pipes when transitioning between a flanged component and a compatible socket-and-spigot pipeline.
Check the standard, drilling dimensions and face requirements before installation. Components from different standard systems may not be compatible despite similar nominal designations.
No. PN and C class belong to different designation systems. Specify the flange PN designation and the required pipe wall or performance specification separately.
Custom lengths can be reviewed against your drawing and manufacturing limits. For double-flanged pipes, state the required face-to-face length and tolerance. For mixed-end pipes, define the measurement points and installed-length requirements.
They should be listed explicitly in the quotation. Specify gasket dimensions and material, fastener requirements and quantities to ensure a complete connection package.
A flange joint is rigid and should not be used to absorb significant misalignment or ground movement. Where flexibility is required, the pipeline design should provide suitable components and supports.
Confirm the complete supplied configuration, including lining, gaskets and applicable water-contact approvals. A pipe or flange standard alone does not establish every drinking-water approval.
Suitability depends on the project design, corrosion protection, support and restraint arrangements, settlement conditions and access requirements. Flanged pipework is commonly selected for equipment connections and accessible chambers; buried applications require specific review.
Specify the required dimensional, material, lining/coating and pressure-test records. Additional inspection or third-party witnessing should be agreed before production.
Send ZSJH your drawings, specification or bill of quantities for a project-specific offer.
Please include:
Required product standard and edition
DN and quantity for each item
Double-flanged, flange-and-spigot or flange-and-socket configuration
Flange standard, PN designation and sealing-face requirements
Face-to-face or drawing-defined length and tolerance
Bolt-hole orientation requirements
Operating pressure, surge, temperature and conveyed medium
Internal lining and external coating requirements
Gaskets and fasteners required
Inspection documents and approval requirements
Delivery destination and target schedule
Request a Quotation for Flanged Ductile Iron Pipe
Provide the connection details and installation dimensions so the proposed supply can be checked against your project requirements.
content is empty!