Views: 0 Author: Site Editor Publish Time: 2026-08-17 Origin: Site
Accurate quantity calculation is an important part of steel structure workshop design, fabrication, cost estimation, and project budgeting. A complete steel building quantity takeoff normally includes structural steel members, roof and wall systems, waterproofing, drainage, corrosion protection, insulation, and other related components.
Different components are measured using different methods. Structural steel is generally calculated by weight, while roofing, wall panels, waterproofing, and protective layers are usually calculated by area.
Below is a practical overview of the common calculation methods used for steel structure workshop projects.
Steel roof trusses and space frame structures are generally calculated according to the dimensions shown on the design drawings.
Quantities are calculated based on the weight of structural steel shown in the drawings.
The weight of bolt holes, cut edges, notches, and similar processing areas is generally not deducted.
Welding electrodes, rivets, bolts, and other connection materials are normally not added separately to the theoretical steel weight unless otherwise specified.
Irregular or polygonal steel plates can be calculated according to the area of their enclosing rectangular shape where the applicable measurement rules require it.
Space frame quantities should distinguish between different connection systems, such as bolted ball joints, welded ball joints, and steel plate joints.
Unit of measurement: metric ton (t)
Steel brackets and trusses are also normally calculated according to the theoretical steel weight indicated on the structural drawings.
Calculate according to the dimensions and steel sections specified in the drawings.
Openings, edge cutting, and local notches are generally not deducted from the theoretical steel weight.
Welding consumables, bolts, and rivets are normally not included as additional structural steel weight.
Irregular steel plates may be calculated using the enclosing rectangular dimensions according to the applicable quantity measurement method.
Unit of measurement: metric ton (t)
Steel columns and beams are some of the most important components in a steel structure workshop or industrial steel building.
Typical components include:
H-section steel columns
Box columns
Steel pipe columns
Built-up steel columns
Steel beams
Roof beams
Crane beams
Other fabricated structural members
The quantity is normally calculated according to the theoretical weight of the steel shown on the design drawings.
For standard steel sections, the basic calculation can be expressed as:
Steel Column Weight = Section Weight per Meter × Column Length × Quantity
For fabricated members, the weight of individual steel plates can be calculated and added together.
Components attached directly to the steel column, such as corbels, brackets, stiffeners, connection plates, reinforcement rings, and internal sleeves, may be included in the total column quantity where applicable.
Steel beam quantities are calculated according to their section size, length, and quantity.
For example:
Steel Beam Weight = Unit Weight × Beam Length × Quantity
If crane beams include braking beams, braking trusses, end stops, or related structural components, these items may be incorporated into the crane beam quantity according to the project measurement requirements.
Unit of measurement: metric ton (t)
Profiled steel floor decking is generally calculated according to the horizontal projected area shown on the drawings.
Columns, local projections, and small openings may not need to be deducted depending on the applicable measurement standard.
A common calculation method is:
Floor Deck Area = Building Length × Building Width – Deductible Openings
If reinforced concrete is poured over the steel deck, the quantities of concrete and reinforcement should be calculated separately.
Unit of measurement: square meter (m²)
Steel wall cladding is calculated according to the actual wall covering area shown on the architectural or structural drawings.
Typical wall systems include:
Corrugated steel sheets
Color-coated steel panels
Sandwich wall panels
Insulated metal panels
Galvanized steel cladding
Small openings may not always be deducted depending on the project measurement rules.
Flashing, corner trims, window sill flashing, edge trims, and similar accessories may be included in the wall cladding system rather than calculated separately.
Unit of measurement: square meter (m²)
A steel structure workshop contains many secondary structural members in addition to the main columns and beams.
These commonly include:
Steel braces
Purlins
Girts
Steel wall frames
Roof bracing
Steel platforms
Walkways
Handrails
Steel stairs
Equipment supports
Steel brackets
Steel funnels
Miscellaneous fabricated steel components
These components are normally calculated according to the theoretical steel weight based on the dimensions indicated on the drawings.
For standard steel sections:
Steel Weight = Unit Weight × Length × Quantity
For steel plates:
Steel Plate Weight = Length × Width × Thickness × Steel Density
The commonly used density of carbon steel is approximately:
7,850 kg/m³
Unit of measurement: metric ton (t)
Roof panels are normally calculated based on the actual sloped roof area, rather than simply using the horizontal building footprint.
The general calculation is:
Roof Area = Roof Slope Length × Building Length
For a double-slope roof, calculate both sides of the roof.
Roofing materials may include:
Corrugated steel roofing sheets
Color-coated steel roof panels
Insulated sandwich panels
FRP roofing sheets
Polycarbonate roof panels
Small roof penetrations, ventilation bases, ducts, or minor openings may not always be deducted depending on the applicable project measurement standard.
Unit of measurement: square meter (m²)
Waterproofing quantity is generally calculated according to the actual waterproofed surface area.
Calculate according to the actual sloped surface area.
Calculate according to the horizontal projected area.
Common waterproofing materials include:
Waterproof membranes
Modified bitumen membranes
PVC waterproof membranes
Polymer waterproof coatings
Bituminous waterproof coatings
Additional waterproofing around parapets, expansion joints, roof openings, and skylights should be included where required.
Unit of measurement: square meter (m²)
Rigid waterproofing systems are normally calculated according to the actual treated roof area shown on the drawings.
Depending on the applicable measurement standard, small roof penetrations may not need to be deducted.
Unit of measurement: square meter (m²)
Rainwater downpipes are calculated according to their installed length.
If the exact length is not shown on the drawing, it can generally be estimated from the roof eave level to the designed discharge level.
The basic formula is:
Total Downpipe Length = Length per Downpipe × Number of Downpipes
Unit of measurement: meter (m)
Steel gutters are generally calculated according to their dimensions shown on the drawings.
For sheet metal gutters, the quantity can be calculated according to the developed surface area of the gutter.
The calculation may consider:
Gutter length
Bottom width
Side height
Folded edges
Connection details
Unit of measurement: square meter (m²) or meter (m), depending on the project specification
Membrane waterproofing, coating waterproofing, and rigid waterproofing systems are normally calculated according to the actual treated surface area.
Floor waterproofing is calculated according to the clear area between the main walls.
Large equipment foundations, pits, and permanent structures occupying the floor area should normally be deducted where required.
Wall waterproofing is calculated according to the actual waterproofed wall surface shown in the drawings.
Unit of measurement: square meter (m²)
Expansion joints, settlement joints, and other deformation joints are usually calculated according to their designed length.
The general formula is:
Joint Quantity = Total Designed Joint Length
Unit of measurement: meter (m)
Steel structures usually require surface protection to improve durability and corrosion resistance.
Common anti-corrosion systems include:
Anti-corrosion primer
Epoxy coating
Zinc-rich primer
Polyurethane coating
Fire-resistant coating
Galvanizing
Other industrial protective coatings
Coating quantities are generally calculated according to the actual surface area of the steel members.
For example:
Coating Area = Surface Area per Meter × Member Length × Quantity
The required coating quantity will also depend on:
Number of coating layers
Dry film thickness
Coating coverage rate
Steel surface condition
Surface preparation method
Unit of measurement: square meter (m²)
Anti-corrosion coatings, protective layers, resin systems, and other surface treatments are generally calculated according to the actual treated surface area.
For vertical structural surfaces, projecting portions should normally be included according to their developed surface area.
Unit of measurement: square meter (m²)
Thermal insulation is another important part of many industrial steel buildings.
Common insulation materials include:
Rock wool
Glass wool
EPS sandwich panels
PU sandwich panels
PIR sandwich panels
Roof insulation is normally calculated according to the roof covering area, while wall insulation is calculated according to the wall cladding area.
Unit of measurement: square meter (m²)
For preliminary steel structure estimation, the following formula is widely used:
Steel Weight (kg) = Volume (m³) × 7,850 kg/m³
For a steel plate:
Weight = Length × Width × Thickness × 7,850
For example, a steel plate measuring:
Length: 6 m
Width: 1.5 m
Thickness: 10 mm (0.01 m)
The theoretical weight is:
6 × 1.5 × 0.01 × 7,850 = 706.5 kg
This method can be used for steel plates, built-up columns, fabricated beams, stiffeners, connection plates, and many other structural steel components.
For a complete steel structure workshop cost estimation, we recommend checking at least the following items:
Main steel columns
Main steel beams and roof rafters
Crane beams
Roof and wall bracing
Purlins and girts
Tie rods and secondary members
Connection plates and stiffeners
Steel stairs and platforms
Roof panels
Wall cladding
Insulation materials
Doors and windows
Roof gutters
Rainwater downpipes
Bolts and fasteners
Surface treatment and painting
Fireproof coating, if required
Packing and transportation requirements
A detailed quantity takeoff helps reduce material waste, improve quotation accuracy, and provide a more reliable basis for steel fabrication and project budgeting.
ZSJH STEEL provides steel structure design, fabrication, material supply, quality inspection, export packaging, and international delivery services for industrial and commercial steel building projects.
Our products and solutions can be customized according to project drawings, technical specifications, structural loads, material standards, and local construction requirements.
Our steel structure solutions are suitable for:
Steel structure workshops
Industrial factories
Steel warehouses
Logistics centers
Manufacturing plants
Commercial steel buildings
Agricultural buildings
Aircraft hangars
Multi-story steel buildings
Custom structural steel projects
If you are planning a steel structure project, send us your architectural drawings, structural drawings, dimensions, design loads, material requirements, and project location. Our team can assist with quantity evaluation, fabrication planning, and quotation preparation.
Contact ZSJH STEEL for a customized steel structure solution and project quotation.
content is empty!